<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Widman, Guido</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Tangermann, Michael</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Voluntary brain regulation and communication with electrocorticogram signals.</style></title><secondary-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Biofeedback, Psychology</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Dominance, Cerebral</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsies, Partial</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Activity</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Software</style></keyword><keyword><style  face="normal" font="default" size="100%">Somatosensory Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Theta Rhythm</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Writing</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18495541</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">13</style></volume><pages><style face="normal" font="default" size="100%">300-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(BCIs) can be used for communication in writing without muscular activity or for learning to control seizures by voluntary regulation of&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;signals such as the electroencephalogram (EEG). Three of five patients with epilepsy were able to spell their names with electrocorticogram (ECoG) signals derived from motor-related areas within only one or two training sessions. Imagery of finger or tongue movements was classified with support-vector classification of autoregressive coefficients derived from the ECoG signals. After training of the classifier, binary classification responses were used to select letters from a&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;-generated menu. Offline analysis showed increased theta activity in the unsuccessful patients, whereas the successful patients exhibited dominant sensorimotor rhythms that they could control. The high spatial resolution and increased signal-to-noise ratio in ECoG signals, combined with short training periods, may offer an alternative for communication in complete paralysis, locked-in syndrome, and motor restoration.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Nijboer, F</style></author><author><style face="normal" font="default" size="100%">Kübler, A.</style></author><author><style face="normal" font="default" size="100%">Matuz, T.</style></author><author><style face="normal" font="default" size="100%">Adrian Furdea</style></author><author><style face="normal" font="default" size="100%">Mochty, Ursula</style></author><author><style face="normal" font="default" size="100%">Jordan, M.</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Bensch, M</style></author><author><style face="normal" font="default" size="100%">Tangermann, Michael</style></author><author><style face="normal" font="default" size="100%">Widmann, G.</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain Computer Interfaces for Communication in Paralysis: a Clinical-Experimental Approach.</style></title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interfaces</style></keyword><keyword><style  face="normal" font="default" size="100%">EEG</style></keyword><keyword><style  face="normal" font="default" size="100%">experiment</style></keyword><keyword><style  face="normal" font="default" size="100%">Medical sciences Medicine</style></keyword><keyword><style  face="normal" font="default" size="100%">paralyzed patients</style></keyword><keyword><style  face="normal" font="default" size="100%">slow cortical potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Thought-Translation Device</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2007</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://psydok.sulb.uni-saarland.de/volltexte/2008/2154/</style></url></web-urls></urls><publisher><style face="normal" font="default" size="100%">Virtual Library of Psychology at Saarland University and State Library, GERMANY, PsyDok [http://psydok.sulb.uni-saarland.de/phpoai/oai2.php] (Germany)</style></publisher><isbn><style face="normal" font="default" size="100%">9780262256049</style></isbn><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;color: #333333; font-family: sans-serif; font-size: 15px; line-height: 24px;&quot;&gt;An overview of different approaches to brain-computer interfaces (BCIs) developed in our laboratory is given. An important clinical application of BCIs is to enable communication or environmental control in severely paralyzed patients. The BCI “Thought-Translation Device (TTD)” allows verbal communication through the voluntary self-regulation of brain signals (e.g., slow cortical potentials (SCPs)), which is achieved by operant feedback training. Humans' ability to self-regulate their SCPs is used to move a cursor toward a target that contains a selectable letter set. Two different approaches were followed to developWeb browsers that could be controlled with binary brain responses. Implementing more powerful classification methods including different signal parameters such as oscillatory features improved our BCI considerably. It was also tested on signals with implanted electrodes. Most BCIs provide the user with a visual feedback interface. Visually impaired patients require an auditory feedback mode. A procedure using auditory (sonified) feedback of multiple EEG parameters was evaluated. Properties of the auditory systems are reported and the results of two experiments with auditory feedback are presented. Clinical data of eight ALS patients demonstrated that all patients were able to acquire efficient brain control of one of the three available BCI systems (SCP, µ-rhythm, and P300), most of them used the SCP-BCI. A controlled comparison of the three systems in a group of ALS patients, however, showed that P300-BCI and the µ-BCI are faster and more easily acquired than SCP-BCI, at least in patients with some rudimentary motor control left. Six patients who started BCI training after entering the completely locked-in state did not achieve reliable communication skills with any BCI system. One completely locked-in patient was able t o communicate shortly with a ph-meter, but lost control afterward.&lt;/span&gt;&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Wilhelm, Barbara</style></author><author><style face="normal" font="default" size="100%">Nijboer, F</style></author><author><style face="normal" font="default" size="100%">Mochty, Ursula</style></author><author><style face="normal" font="default" size="100%">Widman, Guido</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Kübler, A.</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Classifying EEG and ECoG signals without subject training for fast BCI implementation: comparison of nonparalyzed and completely paralyzed subjects.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Artificial Intelligence</style></keyword><keyword><style  face="normal" font="default" size="100%">Cluster Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer User Training</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Paralysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Pattern Recognition, Automated</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792289</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">183-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;We summarize results from a series of related studies that aim to develop a motor-imagery-&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;based&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain-computer interface&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;using a single recording session of electroencephalogram (EEG) or electrocorticogram (ECoG) signals for each subject. We apply the same experimental and analytical methods to 11 nonparalysed subjects (eight EEG, three ECoG), and to five paralyzed subjects (four EEG, one ECoG) who had been unable to communicate for some time. While it was relatively easy to obtain classifiable signals quickly from most of the nonparalyzed subjects, it proved impossible to classify the signals obtained from the paralyzed patients by the same methods. This highlights the fact that though certain BCI paradigms may work well with healthy subjects, this does not necessarily indicate success with the target user group. We outline possible reasons for this failure to transfer.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Widman, Guido</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors><secondary-authors><author><style face="normal" font="default" size="100%">Franke, Katrin</style></author><author><style face="normal" font="default" size="100%">Müller, Klaus-Robert</style></author><author><style face="normal" font="default" size="100%">Nickolay, Bertram</style></author><author><style face="normal" font="default" size="100%">Schäfer, Ralf</style></author></secondary-authors></contributors><titles><title><style face="normal" font="default" size="100%">Classifying Event-Related Desynchronization in EEG, ECoG and MEG Signals.</style></title><secondary-title><style face="normal" font="default" size="100%">Pattern Recognition</style></secondary-title><tertiary-title><style face="normal" font="default" size="100%">Lecture Notes in Computer Science</style></tertiary-title></titles><dates><year><style  face="normal" font="default" size="100%">2006</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://dx.doi.org/10.1007/11861898_41</style></url></web-urls></urls><publisher><style face="normal" font="default" size="100%">Springer Berlin / Heidelberg</style></publisher><volume><style face="normal" font="default" size="100%">4174</style></volume><pages><style face="normal" font="default" size="100%">404-413</style></pages><isbn><style face="normal" font="default" size="100%">978-3-540-44412-1</style></isbn><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;color: #333333; font-family: 'Helvetica Neue', Arial, Helvetica, sans-serif; font-size: 13px; line-height: 20px;&quot;&gt;We employed three different brain signal recording methods to perform Brain-Computer Interface studies on untrained subjects. In all cases, we aim to develop a system that could be used for fast, reliable preliminary screening in clinical BCI application, and we are interested in knowing how long screening sessions need to be. Good performance could be achieved, on average, after the first 200 trials in EEG, 75–100 trials in MEG, or 25–50 trials in ECoG. We compare the performance of Independent Component Analysis and the Common Spatial Pattern algorithm in each of the three sensor types, finding that spatial filtering does not help in MEG, helps a little in ECoG, and improves performance a great deal in EEG. In all cases the unsupervised ICA algorithm performed at least as well as the supervised CSP algorithm, which can suffer from poor generalization performance due to overfitting, particularly in ECoG and MEG.&lt;/span&gt;&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Schroeder, Michael</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Preissl, Hubert</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Bogdan, Martin</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Schoelkopf, Bernhard</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A Brain Computer Interface with Online Feedback based on Magnetoencephalography.</style></title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain Computer Interfaces</style></keyword><keyword><style  face="normal" font="default" size="100%">User Modelling for Computer Human Interaction</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2005</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.researchgate.net/publication/221346004_A_brain_computer_interface_with_online_feedback_based_on_magnetoencephalography</style></url></web-urls></urls><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, sans-serif; font-size: 12px; line-height: 16px;&quot;&gt;The aim of this paper is to show that machine learning techniques can be used to derive a classifying function for human brain signal data measured by magnetoencephalography (MEG), for the use in a brain computer interface (BCI). This is especially helpful for evaluating quickly whether a BCI approach based on electroencephalography, on which training may be slower due to lower signalto-noise ratio, is likely to succeed. We apply RCE and regularized SVMs to the experimental data of ten healthy subjects performing a motor imagery task. Four subjects were able to use a trained classifier to write a short name. Further analysis gives evidence that the proposed imagination task is suboptimal for the possible extension to a multiclass interface. To the best of our knowledge this paper is the first working online MEG-based BCI and is therefore a “proof of concept”.&lt;/span&gt;&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Widman, Guido</style></author><author><style face="normal" font="default" size="100%">Schroeder, Michael</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Methods Towards Invasive Human Brain Computer Interfaces.</style></title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain Computer Interfaces</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">2005</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.64.8486</style></url></web-urls></urls><isbn><style face="normal" font="default" size="100%">0-262-19534-8</style></isbn><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;div class=&quot;page&quot; title=&quot;Page 1&quot;&gt;
&lt;div class=&quot;layoutArea&quot;&gt;
&lt;div class=&quot;column&quot;&gt;
&lt;p&gt;&lt;span style=&quot;font-size: 10.000000pt; font-family: 'Times';&quot;&gt;During the last ten years there has been growing interest in the develop- ment of Brain Computer Interfaces (BCIs). The field has mainly been driven by the needs of completely paralyzed patients to communicate. With a few exceptions, most human BCIs are based on extracranial elec- troencephalography (EEG). However, reported bit rates are still low. One reason for this is the low signal-to-noise ratio of the EEG [16]. We are currently investigating if BCIs based on electrocorticography (ECoG) are a viable alternative. In this paper we present the method and examples of intracranial EEG recordings of three epilepsy patients with electrode grids placed on the motor cortex. The patients were asked to repeat- edly imagine movements of two kinds, e.g., tongue or finger movements. We analyze the classifiability of the data using Support Vector Machines (SVMs) [18, 21] and Recursive Channel Elimination (RCE) [11].&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;/div&gt;
&lt;/div&gt;
&lt;/div&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Bogdan, Martin</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author></authors><secondary-authors><author><style face="normal" font="default" size="100%">Vesin J M, T EbrahimiEditor</style></author></secondary-authors></contributors><titles><title><style face="normal" font="default" size="100%">Robust EEG Channel Selection across Subjects for Brain-Computer Interfaces.</style></title><secondary-title><style face="normal" font="default" size="100%">EURASIP Journal on Advances in Signal Processing</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">channel selection</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">feature selection</style></keyword><keyword><style  face="normal" font="default" size="100%">recursive channel elimination</style></keyword><keyword><style  face="normal" font="default" size="100%">support vector machine</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">01/2005</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.researchgate.net/publication/26532072_Robust_EEG_Channel_Selection_across_Subjects_for_Brain-Computer_Interfaces</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">2005</style></volume><pages><style face="normal" font="default" size="100%">3103–3112</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Most EEG-based brain-computer interface (BCI) paradigms come along with specific electrode positions, for example, for a visual-based BCI, electrode positions close to the primary visual cortex are used. For new BCI paradigms it is usually not known where task relevant activity can be measured from the scalp. For individual subjects, Lal et al. in 2004 showed that recording positions can be found without the use of prior knowledge about the paradigm used. However it remains unclear to what extent their method of recursive channel elimination (RCE) can be generalized across subjects. In this paper we transfer channel rankings from a group of subjects to a new subject. For motor imagery tasks the results are promising, although cross-subject channel selection does not quite achieve the performance of channel selection on data of single subjects. Although the RCE method was not provided with prior knowledge about the mental task, channels that are well known to be important (from a physiological point of view) were consistently selected whereas task-irrelevant channels were reliably disregarded.&lt;em&gt;&lt;br /&gt;&lt;/em&gt;&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Benjamin Blankertz</style></author><author><style face="normal" font="default" size="100%">Müller, Klaus-Robert</style></author><author><style face="normal" font="default" size="100%">Curio, Gabriel</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Schlögl, Alois</style></author><author><style face="normal" font="default" size="100%">Neuper, Christa</style></author><author><style face="normal" font="default" size="100%">Pfurtscheller, Gert</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The BCI Competition 2003: Progress and perspectives in detection and discrimination of EEG single trials.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Artificial Intelligence</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Databases, Factual</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensitivity and Specificity</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">51</style></volume><pages><style face="normal" font="default" size="100%">1044-51</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Interest in developing a new method of man-to-machine communication--a brain-computer interface (BCI)--has grown steadily over the past few decades. BCIs create a new communication channel between the brain and an output device by bypassing conventional motor output pathways of nerves and muscles. These systems use signals recorded from the scalp, the surface of the cortex, or from inside the brain to enable users to control a variety of applications including simple word-processing software and orthotics. BCI technology could therefore provide a new communication and control option for individuals who cannot otherwise express their wishes to the outside world. Signal processing and classification methods are essential tools in the development of improved BCI technology. We organized the BCI Competition 2003 to evaluate the current state of the art of these tools. Four laboratories well versed in EEG-based BCI research provided six data sets in a documented format. We made these data sets (i.e., labeled training sets and unlabeled test sets) and their descriptions available on the Internet. The goal in the competition was to maximize the performance measure for the test labels. Researchers worldwide tested their algorithms and competed for the best classification results. This paper describes the six data sets and the results and function of the most successful algorithms.</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">BCI2000: a general-purpose brain-computer interface (BCI) system.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Peripherals</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Failure Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Systems Integration</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">51</style></volume><pages><style face="normal" font="default" size="100%">1034-43</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Many laboratories have begun to develop brain-computer interface (BCI) systems that provide communication and control capabilities to people with severe motor disabilities. Further progress and realization of practical applications depends on systematic evaluations and comparisons of different brain signals, recording methods, processing algorithms, output formats, and operating protocols. However, the typical BCI system is designed specifically for one particular BCI method and is, therefore, not suited to the systematic studies that are essential for continued progress. In response to this problem, we have developed a documented general-purpose BCI research and development platform called BCI2000. BCI2000 can incorporate alone or in combination any brain signals, signal processing methods, output devices, and operating protocols. This report is intended to describe to investigators, biomedical engineers, and computer scientists the concepts that the BC12000 system is based upon and gives examples of successful BCI implementations using this system. To date, we have used BCI2000 to create BCI systems for a variety of brain signals, processing methods, and applications. The data show that these systems function well in online operation and that BCI2000 satisfies the stringent real-time requirements of BCI systems. By substantially reducing labor and cost, BCI2000 facilitates the implementation of different BCI systems and other psychophysiological experiments. It is available with full documentation and free of charge for research or educational purposes and is currently being used in a variety of studies by many research groups.</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record></records></xml>