<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Korostenskaja, Milena</style></author><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Rose, Douglas F</style></author><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Leach, James</style></author><author><style face="normal" font="default" size="100%">Mangano,  Francesco T</style></author><author><style face="normal" font="default" size="100%">Fujiwara, Hisako</style></author><author><style face="normal" font="default" size="100%">Rozhkov, Leonid</style></author><author><style face="normal" font="default" size="100%">Harris, Elana</style></author><author><style face="normal" font="default" size="100%">Chen, Po-Ching</style></author><author><style face="normal" font="default" size="100%">Seo, Joo-Hee</style></author><author><style face="normal" font="default" size="100%">Lee, Ki H</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Real-Time Functional Mapping with Electrocorticography in Pediatric Epilepsy: Comparison with fMRI and ESM Findings.</style></title><secondary-title><style face="normal" font="default" size="100%">Clinical EEG and neuroscience</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain-computer interface (BCI)</style></keyword><keyword><style  face="normal" font="default" size="100%">cortical stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">electrocorticography (ECoG)</style></keyword><keyword><style  face="normal" font="default" size="100%">epilepsy surgery</style></keyword><keyword><style  face="normal" font="default" size="100%">functional magnetic resonance imaging (fMRI)</style></keyword><keyword><style  face="normal" font="default" size="100%">functional mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">pediatrics</style></keyword><keyword><style  face="normal" font="default" size="100%">SIGFRIED</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2014</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2014</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/24293161</style></url></web-urls></urls><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">SIGFRIED (SIGnal modeling For Real-time Identification and Event Detection) software provides real-time functional mapping (RTFM) of eloquent cortex for epilepsy patients preparing to undergo resective surgery. This study presents the first application of paradigms used in functional magnetic resonance (fMRI) and electrical cortical stimulation mapping (ESM) studies for shared functional cortical mapping in the context of RTFM. Results from the 3 modalities are compared. A left-handed 13-year-old male with intractable epilepsy participated in functional mapping for localization of eloquent language cortex with fMRI, ESM, and RTFM. For RTFM, data were acquired over the frontal and temporal cortex. Several paradigms were sequentially presented: passive (listening to stories) and active (picture naming and verb generation). For verb generation and story processing, fMRI showed atypical right lateralizing language activation within temporal lobe regions of interest and bilateral frontal activation with slight right lateralization. Left hemisphere ESM demonstrated no eloquent language areas. RTFM procedures using story processing and picture naming elicited activity in the right lateral and basal temporal regions. Verb generation elicited strong right lateral temporal lobe activation, as well as left frontal lobe activation. RTFM results confirmed atypical language lateralization evident from fMRI and ESM. We demonstrated the feasibility and usefulness of a new RTFM stimulation paradigm during presurgical evaluation. Block design paradigms used in fMRI may be optimal for this purpose. Further development is needed to create age-appropriate RTFM test batteries.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Guger, C</style></author><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author></authors><secondary-authors><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">E. Winter-Wolpaw</style></author></secondary-authors></contributors><titles><title><style face="normal" font="default" size="100%">Hardware and Software Technologies.</style></title><secondary-title><style face="normal" font="default" size="100%">Brain-Computer Interfaces: Principles and Practice</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2012</style></year></dates><publisher><style face="normal" font="default" size="100%">Oxford University Press</style></publisher><language><style face="normal" font="default" size="100%">eng</style></language></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A procedure for measuring latencies in brain-computer interfaces.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Neurological</style></keyword><keyword><style  face="normal" font="default" size="100%">Reproducibility of Results</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Time Factors</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20403781</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">57</style></volume><pages><style face="normal" font="default" size="100%">1785-97</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interface (BCI) systems must process neural signals with consistent timing in order to support adequate system performance. Thus, it is important to have the capability to determine whether a particular BCI configuration (i.e., hardware and software) provides adequate timing performance for a particular experiment. This report presents a method of measuring and quantifying different aspects of system timing in several typical BCI experiments across a range of settings, and presents comprehensive measures of expected overall system latency for each experimental configuration.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">7</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>5</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors><secondary-authors><author><style face="normal" font="default" size="100%">A. Nijholt</style></author><author><style face="normal" font="default" size="100%">D. Tan</style></author></secondary-authors></contributors><titles><title><style face="normal" font="default" size="100%">Using BCI2000 for HCI-Centered BCI Research.</style></title><secondary-title><style face="normal" font="default" size="100%">Brain-Computer Interfaces: Applying our Minds to Human-Computer Interaction</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2010</style></year></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://link.springer.com/chapter/10.1007%2F978-1-84996-272-8_15</style></url></web-urls></urls><publisher><style face="normal" font="default" size="100%">Springer London</style></publisher><pages><style face="normal" font="default" size="100%">261-274</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">BCI2000 is a general-purpose software suite designed for brain-computer interface (BCI) and related research. BCI2000 has been in development since 2000 and is currently used in close to 500 laboratories around the world. BCI2000 can provide stimulus presentation while simultaneously recording brain signals and subject responses from a number of data acquisition and input devices, respectively. Furthermore, BCI2000 provides a number of services (such as a generic data format that can accommodate any hardware or experimental setup) that can greatly facilitate research. In summary, BCI2000 is ideally suited to support investigations in the area of human-computer interfaces (HCI), in particular those that include recording and processing of brain signals. This chapter provides an overview of the BCI2000 system, and gives examples of its utility for HCI research.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">A L Ritaccio</style></author><author><style face="normal" font="default" size="100%">Lynch, Timothy M</style></author><author><style face="normal" font="default" size="100%">Emrich, Joseph F</style></author><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author><author><style face="normal" font="default" size="100%">Aarnoutse, Erik J</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author><author><style face="normal" font="default" size="100%">H Bischof</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A practical procedure for real-time functional mapping of eloquent cortex using electrocorticographic signals in humans.</style></title><secondary-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Electric Stimulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Practice Guidelines as Topic</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Young Adult</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19366638</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">15</style></volume><pages><style face="normal" font="default" size="100%">278-86</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Functional mapping of eloquent cortex is often necessary prior to invasive brain surgery, but current techniques that derive this mapping have important limitations. In this article, we demonstrate the first comprehensive evaluation of a rapid, robust, and practical mapping system that uses passive recordings of electrocorticographic signals. This mapping procedure is based on the BCI2000 and SIGFRIED technologies that we have been developing over the past several years. In our study, we evaluated 10 patients with epilepsy from four different institutions and compared the results of our procedure with the results derived using electrical cortical stimulation (ECS) mapping. The results show that our procedure derives a functional motor cortical map in only a few minutes. They also show a substantial concurrence with the results derived using ECS mapping. Specifically, compared with ECS maps, a next-neighbor evaluation showed no false negatives, and only 0.46 and 1.10% false positives for hand and tongue maps, respectively. In summary, we demonstrate the first comprehensive evaluation of a practical and robust mapping procedure that could become a new tool for planning of invasive brain surgeries.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Walton, Léo M</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using an EEG-based brain-computer interface for virtual cursor movement with BCI2000.</style></title><secondary-title><style face="normal" font="default" size="100%">J Vis Exp</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Vis Exp</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Calibration</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19641479</style></url></web-urls></urls><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A brain-computer interface (BCI) functions by translating a neural signal, such as the electroencephalogram (EEG), into a signal that can be used to control a computer or other device. The amplitude of the EEG signals in selected frequency bins are measured and translated into a device command, in this case the horizontal and vertical velocity of a computer cursor. First, the EEG electrodes are applied to the user s scalp using a cap to record brain activity. Next, a calibration procedure is used to find the EEG electrodes and features that the user will learn to voluntarily modulate to use the BCI. In humans, the power in the mu (8-12 Hz) and beta (18-28 Hz) frequency bands decrease in amplitude during a real or imagined movement. These changes can be detected in the EEG in real-time, and used to control a BCI ([1],[2]). Therefore, during a screening test, the user is asked to make several different imagined movements with their hands and feet to determine the unique EEG features that change with the imagined movements. The results from this calibration will show the best channels to use, which are configured so that amplitude changes in the mu and beta frequency bands move the cursor either horizontally or vertically. In this experiment, the general purpose BCI system BCI2000 is used to control signal acquisition, signal processing, and feedback to the user [3].&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">29</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Miller, K.J.</style></author><author><style face="normal" font="default" size="100%">Nicholas R Anderson</style></author><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Smyth, Matt</style></author><author><style face="normal" font="default" size="100%">Ojemann, J G</style></author><author><style face="normal" font="default" size="100%">Moran, D</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Two-dimensional movement control using electrocorticographic signals in humans.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neural Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neural Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adolescent</style></keyword><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Data Interpretation, Statistical</style></keyword><keyword><style  face="normal" font="default" size="100%">Drug Resistance</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Movement</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">03/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18310813</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">5</style></volume><pages><style face="normal" font="default" size="100%">75-84</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;We show here that a&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain-computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;interface (BCI) using electrocorticographic activity (ECoG) and imagined or overt motor tasks enables humans to control a&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;cursor in two dimensions. Over a brief training period of 12-36 min, each of five human subjects acquired substantial control of particular ECoG features recorded from several locations over the same hemisphere, and achieved average success rates of 53-73% in a two-dimensional four-target center-out task in which chance accuracy was 25%. Our results support the expectation that ECoG-based BCIs can combine high performance with technical and&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;clinical&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;practicality, and also indicate promising directions for further research.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Felton, Elizabeth A</style></author><author><style face="normal" font="default" size="100%">Garell, P Charles</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">ECoG factors underlying multimodal control of a brain-computer interface.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Peripherals</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Man-Machine Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Systems Integration</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Volition</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792305</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">246-50</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Most current brain-computer interface (BCI) systems for humans use electroencephalographic activity recorded from the scalp, and may be limited in many ways. Electrocorticography (ECoG) is believed to be a minimally-invasive alternative to electroencephalogram (&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;EEG&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;) for BCI systems, yielding superior signal characteristics that could allow rapid user training and faster communication rates. In addition, our preliminary results suggest that brain regions other than the sensorimotor cortex, such as auditory cortex, may be trained to control a BCI system using similar methods as those used to train motor regions of the brain. This could prove to be vital for users who have neurological disease, head trauma, or other conditions precluding the use of sensorimotor cortex for BCI control.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record></records></xml>