<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Vansteensel, Mariska J</style></author><author><style face="normal" font="default" size="100%">Hermes, Dora</style></author><author><style face="normal" font="default" size="100%">Aarnoutse, Erik J</style></author><author><style face="normal" font="default" size="100%">Bleichner, Martin G</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">van Rijen, Peter C</style></author><author><style face="normal" font="default" size="100%">Leijten, Frans S S</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer interfacing based on cognitive control.</style></title><secondary-title><style face="normal" font="default" size="100%">Ann Neurol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Ann. Neurol.</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuropsychological Tests</style></keyword><keyword><style  face="normal" font="default" size="100%">Oxygen</style></keyword><keyword><style  face="normal" font="default" size="100%">Prefrontal Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Spectrum Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Time Factors</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20517943</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">67</style></volume><pages><style face="normal" font="default" size="100%">809-16</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;OBJECTIVE:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces (BCIs) translate deliberate intentions and associated changes in brain activity into action, thereby offering patients with severe paralysis an alternative means of communication with and control over their environment. Such systems are not available yet, partly due to the high performance standard that is required. A major challenge in the development of implantable BCIs is to identify cortical regions and related functions that an individual can reliably and consciously manipulate. Research predominantly focuses on the sensorimotor cortex, which can be activated by imagining motor actions. However, because this region may not provide an optimal solution to all patients, other neuronal networks need to be examined. Therefore, we investigated whether the cognitive control network can be used for BCI purposes. We also determined the feasibility of using functional magnetic resonance imaging (fMRI) for noninvasive localization of the cognitive control network.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Three patients with intractable epilepsy, who were temporarily implanted with subdural grid electrodes for diagnostic purposes, attempted to gain BCI control using the electrocorticographic (ECoG) signal of the left dorsolateral prefrontal cortex (DLPFC).&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;All subjects quickly gained accurate BCI control by modulation of gamma-power of the left DLPFC. Prelocalization of the relevant region was performed with fMRI and was confirmed using the ECoG signals obtained during mental calculation localizer tasks.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;INTERPRETATION:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The results indicate that the cognitive control network is a suitable source of signals for BCI applications. They also demonstrate the feasibility of translating understanding about cognitive networks derived from functional neuroimaging into clinical applications.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Adam J Wilson</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Walton, Léo M</style></author><author><style face="normal" font="default" size="100%">Williams, Justin C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Using an EEG-based brain-computer interface for virtual cursor movement with BCI2000.</style></title><secondary-title><style face="normal" font="default" size="100%">J Vis Exp</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Vis Exp</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Calibration</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19641479</style></url></web-urls></urls><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A brain-computer interface (BCI) functions by translating a neural signal, such as the electroencephalogram (EEG), into a signal that can be used to control a computer or other device. The amplitude of the EEG signals in selected frequency bins are measured and translated into a device command, in this case the horizontal and vertical velocity of a computer cursor. First, the EEG electrodes are applied to the user s scalp using a cap to record brain activity. Next, a calibration procedure is used to find the EEG electrodes and features that the user will learn to voluntarily modulate to use the BCI. In humans, the power in the mu (8-12 Hz) and beta (18-28 Hz) frequency bands decrease in amplitude during a real or imagined movement. These changes can be detected in the EEG in real-time, and used to control a BCI ([1],[2]). Therefore, during a screening test, the user is asked to make several different imagined movements with their hands and feet to determine the unique EEG features that change with the imagined movements. The results from this calibration will show the best channels to use, which are configured so that amplitude changes in the mu and beta frequency bands move the cursor either horizontally or vertically. In this experiment, the general purpose BCI system BCI2000 is used to control signal acquisition, signal processing, and feedback to the user [3].&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">29</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>47</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Miller, Kai J</style></author><author><style face="normal" font="default" size="100%">Blakely, Timothy</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">den Nijs, Marcel</style></author><author><style face="normal" font="default" size="100%">Rao, Rajesh PN</style></author><author><style face="normal" font="default" size="100%">Ojemann, Jeffrey G</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Three cases of feature correlation in an electrocorticographic BCI.</style></title><secondary-title><style face="normal" font="default" size="100%">Engineering in Medicine and Biology Society, 2008.</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adolescent</style></keyword><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">automated pattern recognition</style></keyword><keyword><style  face="normal" font="default" size="100%">control systems</style></keyword><keyword><style  face="normal" font="default" size="100%">decorrelation</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">evoked motor potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Feedback</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">frequency</style></keyword><keyword><style  face="normal" font="default" size="100%">hospitals</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing</style></keyword><keyword><style  face="normal" font="default" size="100%">Statistics as Topic</style></keyword><keyword><style  face="normal" font="default" size="100%">Task Performance and Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Tongue</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19163918</style></url></web-urls></urls><publisher><style face="normal" font="default" size="100%">IEEE</style></publisher><pub-location><style face="normal" font="default" size="100%">Vancouver, BC</style></pub-location><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Three human subjects participated in a closed-loop brain computer interface cursor control experiment mediated by implanted subdural electrocorticographic arrays. The paradigm consisted of several stages: baseline recording, hand and tongue motor tasks as the basis for feature selection, two closed-loop one-dimensional feedback experiments with each of these features, and a two-dimensional feedback experiment using both of the features simultaneously. The two selected features were simple channel and frequency band combinations associated with change during hand and tongue movement. Inter-feature correlation and cross-correlation between features during different epochs of each task were quantified for each stage of the experiment. Our anecdotal, three subject, result suggests that while high correlation between horizontal and vertical control signal can initially preclude successful two-dimensional cursor control, a feedback-based learning strategy can be successfully employed by the subject to overcome this limitation and progressively decorrelate these control signals.</style></abstract></record></records></xml>