<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">BCI2000: a general-purpose brain-computer interface (BCI) system.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Peripherals</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Failure Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Systems Integration</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">51</style></volume><pages><style face="normal" font="default" size="100%">1034-43</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Many laboratories have begun to develop brain-computer interface (BCI) systems that provide communication and control capabilities to people with severe motor disabilities. Further progress and realization of practical applications depends on systematic evaluations and comparisons of different brain signals, recording methods, processing algorithms, output formats, and operating protocols. However, the typical BCI system is designed specifically for one particular BCI method and is, therefore, not suited to the systematic studies that are essential for continued progress. In response to this problem, we have developed a documented general-purpose BCI research and development platform called BCI2000. BCI2000 can incorporate alone or in combination any brain signals, signal processing methods, output devices, and operating protocols. This report is intended to describe to investigators, biomedical engineers, and computer scientists the concepts that the BC12000 system is based upon and gives examples of successful BCI implementations using this system. To date, we have used BCI2000 to create BCI systems for a variety of brain signals, processing methods, and applications. The data show that these systems function well in online operation and that BCI2000 satisfies the stringent real-time requirements of BCI systems. By substantially reducing labor and cost, BCI2000 facilitates the implementation of different BCI systems and other psychophysiological experiments. It is available with full documentation and free of charge for research or educational purposes and is currently being used in a variety of studies by many research groups.</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Ojemann, J G</style></author><author><style face="normal" font="default" size="100%">Moran, D</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A brain-computer interface using electrocorticographic signals in humans.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neural Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neural Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Peripherals</style></keyword><keyword><style  face="normal" font="default" size="100%">Diagnosis, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Evoked Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Movement Disorders</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/15876624</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">1</style></volume><pages><style face="normal" font="default" size="100%">63-71</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(BCIs) enable users to control devices with electroencephalographic (EEG) activity from the scalp or with single-neuron activity from within the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;. Both methods have disadvantages: EEG has limited resolution and requires extensive training, while single-neuron recording entails significant clinical risks and has limited stability. We demonstrate here for the first time that electrocorticographic (ECoG) activity recorded from the surface of the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;can enable users to control a one-dimensional&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;cursor rapidly and accurately. We first identified ECoG signals that were associated with different types of motor and speech imagery. Over brief training periods of 3-24 min, four patients then used these signals to master closed-loop control and to achieve success rates of 74-100% in a one-dimensional binary task. In additional open-loop experiments, we found that ECoG signals at frequencies up to 180 Hz encoded substantial information about the direction of two-dimensional joystick movements. Our results suggest that an ECoG-based BCI could provide for people with severe motor disabilities a non-muscular communication and control option that is more powerful than EEG-based BCIs and is potentially more stable and less traumatic than BCIs that use electrodes penetrating the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record></records></xml>