<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Sarnacki, William A.</style></author><author><style face="normal" font="default" size="100%">Townsend, George</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The P300-based brain-computer interface (BCI): effects of stimulus rate.</style></title><secondary-title><style face="normal" font="default" size="100%">Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">neuroprosthesis</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2011</style></year><pub-dates><date><style  face="normal" font="default" size="100%">04/2011</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/21067970</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">122</style></volume><pages><style face="normal" font="default" size="100%">731–737</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">OBJECTIVE:
Brain-computer interface technology can restore communication and control to people who are severely paralyzed. We have developed a non-invasive BCI based on the P300 event-related potential that uses an 8×9 matrix of 72 items that flash in groups of 6. Stimulus presentation rate (i.e., flash rate) is one of several parameters that could affect the speed and accuracy of performance. We studied performance (i.e., accuracy and characters/min) on copy spelling as a function of flash rate.
METHODS:
In the first study of six BCI users, stimulus-on and stimulus-off times were equal and flash rate was 4, 8, 16, or 32 Hz. In the second study of five BCI users, flash rate was varied by changing either the stimulus-on or stimulus-off time.
RESULTS:
For all users, lower flash rates gave higher accuracy. The flash rate that gave the highest characters/min varied across users, ranging from 8 to 32 Hz. However, variations in stimulus-on and stimulus-off times did not themselves significantly affect accuracy. Providing feedback did not affect results in either study suggesting that offline analyses should readily generalize to online performance. However there do appear to be session-specific effects that can influence the generalizability of classifier results.
CONCLUSIONS:
The results show that stimulus presentation (i.e., flash) rate affects the accuracy and speed of P300 BCI performance.
SIGNIFICANCE:
These results extend the range over which slower flash rates increase the amplitude of the P300. Considering also presentation time, the optimal rate differs among users, and thus should be set empirically for each user. Optimal flash rate might also vary with other parameters such as the number of items in the matrix.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">A L Ritaccio</style></author><author><style face="normal" font="default" size="100%">Emrich, Joseph F</style></author><author><style face="normal" font="default" size="100%">H Bischof</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Rapid Communication with a &quot;P300&quot; Matrix Speller Using Electrocorticographic Signals (ECoG).</style></title><secondary-title><style face="normal" font="default" size="100%">Front Neurosci</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Front Neurosci</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocorticography</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potential</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">speller</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2011</style></year><pub-dates><date><style  face="normal" font="default" size="100%">02/2011</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/21369351</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">5</style></volume><pages><style face="normal" font="default" size="100%">5</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain-computer interface&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;BCI&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;) can provide a non-muscular communication channel to severely disabled people. One particular realization of a&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;BCI&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;is the P300 matrix speller that was originally described by Farwell and Donchin (1988). This speller uses event-related potentials (ERPs) that include the P300 ERP. All previous online studies of the P300 matrix speller used scalp-recorded electroencephalography (EEG) and were limited in their communication performance to only a few characters per minute. In our study, we investigated the feasibility of using electrocorticographic (ECoG) signals for online operation of the matrix speller, and determined associated spelling rates. We used the matrix speller that is implemented in the BCI2000 system. This speller used ECoG signals that were recorded from frontal, parietal, and occipital areas in one subject. This subject spelled a total of 444 characters in online experiments. The results showed that the subject sustained a rate of 17&amp;thinsp;characters/min (i.e., 69&amp;thinsp;bits/min), and achieved a peak rate of 22&amp;thinsp;characters/min (i.e., 113&amp;thinsp;bits/min). Detailed analysis of the results suggests that ERPs over visual areas (i.e., visual evoked potentials) contribute significantly to the performance of the matrix speller&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;BCI&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;system. Our results also point to potential reasons for the apparent advantages in spelling performance of ECoG compared to EEG. Thus, with additional verification in more subjects, these results may further extend the communication options for people with serious neuromuscular disabilities.&lt;/span&gt;&lt;/p&gt;</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Townsend, G.</style></author><author><style face="normal" font="default" size="100%">LaPallo, B. K.</style></author><author><style face="normal" font="default" size="100%">Chadwick B. Boulay</style></author><author><style face="normal" font="default" size="100%">Krusienski, D. J.</style></author><author><style face="normal" font="default" size="100%">Frye, G. E.</style></author><author><style face="normal" font="default" size="100%">Hauser, C. K.</style></author><author><style face="normal" font="default" size="100%">Schwartz, N. E.</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Sellers, E. W.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A novel P300-based brain-computer interface stimulus presentation paradigm: moving beyond rows and columns.</style></title><secondary-title><style face="normal" font="default" size="100%">Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-machine interface</style></keyword><keyword><style  face="normal" font="default" size="100%">EEG</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potential</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20347387</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">121</style></volume><pages><style face="normal" font="default" size="100%">1109–1120</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">OBJECTIVE:
An electroencephalographic brain-computer interface (BCI) can provide a non-muscular means of communication for people with amyotrophic lateral sclerosis (ALS) or other neuromuscular disorders. We present a novel P300-based BCI stimulus presentation - the checkerboard paradigm (CBP). CBP performance is compared to that of the standard row/column paradigm (RCP) introduced by Farwell and Donchin (1988).
METHODS:
Using an 8x9 matrix of alphanumeric characters and keyboard commands, 18 participants used the CBP and RCP in counter-balanced fashion. With approximately 9-12 min of calibration data, we used a stepwise linear discriminant analysis for online classification of subsequent data.
RESULTS:
Mean online accuracy was significantly higher for the CBP, 92%, than for the RCP, 77%. Correcting for extra selections due to errors, mean bit rate was also significantly higher for the CBP, 23 bits/min, than for the RCP, 17 bits/min. Moreover, the two paradigms produced significantly different waveforms. Initial tests with three advanced ALS participants produced similar results. Furthermore, these individuals preferred the CBP to the RCP.
CONCLUSIONS:
These results suggest that the CBP is markedly superior to the RCP in performance and user acceptability.
SIGNIFICANCE:
The CBP has the potential to provide a substantially more effective BCI than the RCP. This is especially important for people with severe neuromuscular disabilities.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Klobassa, D. S.</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Peter Brunner</style></author><author><style face="normal" font="default" size="100%">Schwartz, N. E.</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Neuper, C.</style></author><author><style face="normal" font="default" size="100%">Sellers, E. W.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Toward a high-throughput auditory P300-based brain-computer interface.</style></title><secondary-title><style face="normal" font="default" size="100%">Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-machine interface</style></keyword><keyword><style  face="normal" font="default" size="100%">EEG</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potential</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19574091</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">120</style></volume><pages><style face="normal" font="default" size="100%">1252–1261</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">OBJECTIVE:
Brain-computer interface (BCI) technology can provide severely disabled people with non-muscular communication. For those most severely disabled, limitations in eye mobility or visual acuity may necessitate auditory BCI systems. The present study investigates the efficacy of the use of six environmental sounds to operate a 6x6 P300 Speller.
METHODS:
A two-group design was used to ascertain whether participants benefited from visual cues early in training. Group A (N=5) received only auditory stimuli during all 11 sessions, whereas Group AV (N=5) received simultaneous auditory and visual stimuli in initial sessions after which the visual stimuli were systematically removed. Stepwise linear discriminant analysis determined the matrix item that elicited the largest P300 response and thereby identified the desired choice.
RESULTS:
Online results and offline analyses showed that the two groups achieved equivalent accuracy. In the last session, eight of 10 participants achieved 50% or more, and four of these achieved 75% or more, online accuracy (2.8% accuracy expected by chance). Mean bit rates averaged about 2 bits/min, and maximum bit rates reached 5.6 bits/min.
CONCLUSIONS:
This study indicates that an auditory P300 BCI is feasible, that reasonable classification accuracy and rate of communication are achievable, and that the paradigm should be further evaluated with a group of severely disabled participants who have limited visual mobility.
SIGNIFICANCE:
With further development, this auditory P300 BCI could be of substantial value to severely disabled people who cannot use a visual BCI.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Nijboer, F.</style></author><author><style face="normal" font="default" size="100%">Sellers, E. W.</style></author><author><style face="normal" font="default" size="100%">Mellinger, J.</style></author><author><style face="normal" font="default" size="100%">Jordan, M. A.</style></author><author><style face="normal" font="default" size="100%">Matuz, T.</style></author><author><style face="normal" font="default" size="100%">Adrian Furdea</style></author><author><style face="normal" font="default" size="100%">S Halder</style></author><author><style face="normal" font="default" size="100%">Mochty, U.</style></author><author><style face="normal" font="default" size="100%">Krusienski, D. J.</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author><author><style face="normal" font="default" size="100%">Kübler, A.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A P300-based brain-computer interface for people with amyotrophic lateral sclerosis.</style></title><secondary-title><style face="normal" font="default" size="100%">Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">electroencephalogram</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18571984</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">119</style></volume><pages><style face="normal" font="default" size="100%">1909–1916</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">OBJECTIVE:
The current study evaluates the efficacy of a P300-based brain-computer interface (BCI) communication device for individuals with advanced ALS.
METHODS:
Participants attended to one cell of a N x N matrix while the N rows and N columns flashed randomly. Each cell of the matrix contained one character. Every flash of an attended character served as a rare event in an oddball sequence and elicited a P300 response. Classification coefficients derived using a stepwise linear discriminant function were applied to the data after each set of flashes. The character receiving the highest discriminant score was presented as feedback.
RESULTS:
In Phase I, six participants used a 6 x 6 matrix on 12 separate days with a mean rate of 1.2 selections/min and mean online and offline accuracies of 62% and 82%, respectively. In Phase II, four participants used either a 6 x 6 or a 7 x 7 matrix to produce novel and spontaneous statements with a mean online rate of 2.1 selections/min and online accuracy of 79%. The amplitude and latency of the P300 remained stable over 40 weeks.
CONCLUSIONS:
Participants could communicate with the P300-based BCI and performance was stable over many months.
SIGNIFICANCE:
BCIs could provide an alternative communication and control technology in the daily lives of people severely disabled by ALS.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Sellers, Eric W.</style></author><author><style face="normal" font="default" size="100%">Krusienski, Dean J.</style></author><author><style face="normal" font="default" size="100%">Dennis J. McFarland</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">A P300 event-related potential brain-computer interface (BCI): the effects of matrix size and inter stimulus interval on performance.</style></title><secondary-title><style face="normal" font="default" size="100%">Biological psychology</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Amyotrophic Lateral Sclerosis</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">electroencephalogram</style></keyword><keyword><style  face="normal" font="default" size="100%">event-related potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">10/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16860920</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">73</style></volume><pages><style face="normal" font="default" size="100%">242–252</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">We describe a study designed to assess properties of a P300 brain-computer interface (BCI). The BCI presents the user with a matrix containing letters and numbers. The user attends to a character to be communicated and the rows and columns of the matrix briefly intensify. Each time the attended character is intensified it serves as a rare event in an oddball sequence and it elicits a P300 response. The BCI works by detecting which character elicited a P300 response. We manipulated the size of the character matrix (either 3 x 3 or 6 x 6) and the duration of the inter stimulus interval (ISI) between intensifications (either 175 or 350 ms). Online accuracy was highest for the 3 x 3 matrix 175-ms ISI condition, while bit rate was highest for the 6 x 6 matrix 175-ms ISI condition. Average accuracy in the best condition for each subject was 88%. P300 amplitude was significantly greater for the attended stimulus and for the 6 x 6 matrix. This work demonstrates that matrix size and ISI are important variables to consider when optimizing a BCI system for individual users and that a P300-BCI can be used for effective communication.</style></abstract></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Benjamin Blankertz</style></author><author><style face="normal" font="default" size="100%">Müller, Klaus-Robert</style></author><author><style face="normal" font="default" size="100%">Curio, Gabriel</style></author><author><style face="normal" font="default" size="100%">Theresa M Vaughan</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Jonathan Wolpaw</style></author><author><style face="normal" font="default" size="100%">Schlögl, Alois</style></author><author><style face="normal" font="default" size="100%">Neuper, Christa</style></author><author><style face="normal" font="default" size="100%">Pfurtscheller, Gert</style></author><author><style face="normal" font="default" size="100%">Hinterberger, Thilo</style></author><author><style face="normal" font="default" size="100%">Schröder, Michael</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">The BCI Competition 2003: progress and perspectives in detection and discrimination of EEG single trials.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE transactions on bio-medical engineering</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">augmentative communication</style></keyword><keyword><style  face="normal" font="default" size="100%">BCI</style></keyword><keyword><style  face="normal" font="default" size="100%">beta-rhythm</style></keyword><keyword><style  face="normal" font="default" size="100%">brain-computer interface</style></keyword><keyword><style  face="normal" font="default" size="100%">EEG</style></keyword><keyword><style  face="normal" font="default" size="100%">ERP</style></keyword><keyword><style  face="normal" font="default" size="100%">imagined hand movements</style></keyword><keyword><style  face="normal" font="default" size="100%">lateralized readiness potential</style></keyword><keyword><style  face="normal" font="default" size="100%">mu-rhythm</style></keyword><keyword><style  face="normal" font="default" size="100%">P300</style></keyword><keyword><style  face="normal" font="default" size="100%">Rehabilitation</style></keyword><keyword><style  face="normal" font="default" size="100%">single-trial classification</style></keyword><keyword><style  face="normal" font="default" size="100%">slow cortical potentials</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2004</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2004</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/15188876</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">51</style></volume><pages><style face="normal" font="default" size="100%">1044–1051</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">Interest in developing a new method of man-to-machine communication–a brain-computer interface (BCI)–has grown steadily over the past few decades. BCIs create a new communication channel between the brain and an output device by bypassing conventional motor output pathways of nerves and muscles. These systems use signals recorded from the scalp, the surface of the cortex, or from inside the brain to enable users to control a variety of applications including simple word-processing software and orthotics. BCI technology could therefore provide a new communication and control option for individuals who cannot otherwise express their wishes to the outside world. Signal processing and classification methods are essential tools in the development of improved BCI technology. We organized the BCI Competition 2003 to evaluate the current state of the art of these tools. Four laboratories well versed in EEG-based BCI research provided six data sets in a documented format. We made these data sets (i.e., labeled training sets and unlabeled test sets) and their descriptions available on the Internet. The goal in the competition was to maximize the performance measure for the test labels. Researchers worldwide tested their algorithms and competed for the best classification results. This paper describes the six data sets and the results and function of the most successful algorithms.</style></abstract></record></records></xml>