<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gunduz, Aysegul</style></author><author><style face="normal" font="default" size="100%">Sanchez, Justin C</style></author><author><style face="normal" font="default" size="100%">Carney, Paul R</style></author><author><style face="normal" font="default" size="100%">Principe, Jose</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Mapping broadband electrocorticographic recordings to two-dimensional hand trajectories in humans Motor control features.</style></title><secondary-title><style face="normal" font="default" size="100%">Neural Netw</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Neural Netw</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes, Implanted</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodiagnosis</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Feasibility Studies</style></keyword><keyword><style  face="normal" font="default" size="100%">Hand</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Linear Models</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Activity</style></keyword><keyword><style  face="normal" font="default" size="100%">Neural Networks (Computer)</style></keyword><keyword><style  face="normal" font="default" size="100%">Nonlinear Dynamics</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">11/2009</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/19647981</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">22</style></volume><pages><style face="normal" font="default" size="100%">1257-70</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-machine interfaces (BMIs) aim to translate the motor intent of locked-in patients into neuroprosthetic control commands. Electrocorticographical (ECoG) signals provide promising neural inputs to BMIs as shown in recent studies. In this paper, we utilize a broadband spectrum above the fast gamma ranges and systematically study the role of spectral resolution, in which the broadband is partitioned, on the reconstruction of the patients' hand trajectories. Traditionally, the power of ECoG rhythms (&amp;lt;200-300 Hz) has been computed in short duration bins and instantaneously and linearly mapped to cursor trajectories. Neither time embedding, nor nonlinear mappings have been previously implemented in ECoG neuroprosthesis. Herein, mapping of neural modulations to goal-oriented motor behavior is achieved via linear adaptive filters with embedded memory depths and as a novelty through echo state networks (ESNs), which provide nonlinear mappings without compromising training complexity or increasing the number of model parameters, with up to 85% correlation. Reconstructed hand trajectories are analyzed through spatial, spectral and temporal sensitivities. The superiority of nonlinear mappings in the cases of low spectral resolution and abundance of interictal activity is discussed.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">9</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Pei, Xiao-Mei</style></author><author><style face="normal" font="default" size="100%">Zheng, Shi Dong</style></author><author><style face="normal" font="default" size="100%">Zhang, Ai-hua</style></author><author><style face="normal" font="default" size="100%">Duan, Fu-jian</style></author><author><style face="normal" font="default" size="100%">Bin, Guang-yu</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Discussion on &quot;Towards a quantitative characterization of functional states of the brain: from the non-linear methodology to the global linear description&quot; by J. Wackermann.</style></title><secondary-title><style face="normal" font="default" size="100%">Int J Psychophysiol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Int J Psychophysiol</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Diagnostic Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">Functional Laterality</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Linear Models</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Neurological</style></keyword><keyword><style  face="normal" font="default" size="100%">Nonlinear Dynamics</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2005</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2005</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/15866324</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">56</style></volume><pages><style face="normal" font="default" size="100%">201-7</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Wackermann (1999) [Wackermann, J., 1999. Towards a quantitative characterization of functional states of the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;: from the non-linear methodology to the global linear description. Int. J. Psychophysiol. 34, 65-80] proposed Sigma-phi-Omega system for describing the global&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;macro-state, in which Omega complexity was used to quantify the degree of synchrony between spatially distributed EEG processes. In this paper the effect of signal power on Omega complexity is discussed, which was not considered in Wackermann's paper (1999). Then an improved method for eliminating the effect of signal power on Omega complexity is proposed. Finally a case study on the degree of synchrony between two-channel EEG signals over different&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;regions during hand motor imagery is given. The results show that the improved Omega complexity measure would characterize the true degree of synchrony among the EEG signals by eliminating the influence of signal power.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Mandapati, R</style></author><author><style face="normal" font="default" size="100%">Asano, Y</style></author><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Gray, R A</style></author><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantification of effects of global ischemia on dynamics of ventricular fibrillation in isolated rabbit heart.</style></title><secondary-title><style face="normal" font="default" size="100%">Circulation</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Circulation</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrocardiography</style></keyword><keyword><style  face="normal" font="default" size="100%">Linear Models</style></keyword><keyword><style  face="normal" font="default" size="100%">Myocardial Ischemia</style></keyword><keyword><style  face="normal" font="default" size="100%">Rabbits</style></keyword><keyword><style  face="normal" font="default" size="100%">Rotation</style></keyword><keyword><style  face="normal" font="default" size="100%">Sodium Channel Blockers</style></keyword><keyword><style  face="normal" font="default" size="100%">Tetrodotoxin</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Fibrillation</style></keyword><keyword><style  face="normal" font="default" size="100%">Video Recording</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1998</style></year><pub-dates><date><style  face="normal" font="default" size="100%">10/1998</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/9778336</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">98</style></volume><pages><style face="normal" font="default" size="100%">1688-96</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;BACKGROUND:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Ventricular fibrillation (VF) leads to global ischemia of the heart. After 1 to 2 minutes of onset, the VF rate decreases and appears more organized. The objectives of this study were to determine the effects of no-flow global ischemia on nonlinear wave dynamics and establish the mechanism of ischemia-induced slowing of the VF rate.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS AND RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Activation patterns of VF in the Langendorff-perfused rabbit heart were studied with the use of 2 protocols: (1) 15 minutes of no-flow global ischemia followed by reperfusion (n=7) and (2) decreased excitability induced by perfusion with 5 micromol/L of tetrodotoxin (TTX) followed by washout (n=3). Video imaging ( approximately 7500 pixels per frame; 240 frames per second) with a voltage-sensitive dye, ECG, and signal processing (fast Fourier transform) were used for analysis. The dominant frequency of VF decreased from 13.5+/-1.3 during control to 9.3+/-1.4 Hz at 5 minutes of global ischemia (P&amp;lt;0.02). The dominant frequency decreased from 13.9+/-1.1 during control to 7.0+/-0.3 Hz at 2 minutes of TTX infusion (P&amp;lt;0.001). The rotation period of rotors on the epicardial surface (n=27) strongly correlated with the inverse dominant frequency of the corresponding episode of VF (R2=0. 93). The core area, measured for 27 transiently appearing rotors, was 5.3+/-0.7 mm2 during control. A remarkable increase in core area was observed both during global ischemia (13.6+/-1.7 mm2; P&amp;lt;0.001) and TTX perfusion (16.8+/-3.6 mm2; P&amp;lt;0.001). Density of wave fronts decreased during both global ischemia (P&amp;lt;0.002) and TTX perfusion (P&amp;lt;0.002) compared with control.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;CONCLUSIONS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;This study suggests that rotating spiral waves are most likely the underlying mechanism of VF and contribute to its frequency content. Ischemia-induced decrease in the VF rate results from an increase in the rotation period of spiral waves that occurs secondary to an increase in their core area. Remarkably, similar findings in the TTX protocol suggest that reduced excitability during ischemia is an important underlying mechanism for the changes seen.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">16</style></issue></record></records></xml>