<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Loew, L M</style></author><author><style face="normal" font="default" size="100%">Wuskell, J P</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Technical features of a CCD video camera system to record cardiac fluorescence data.</style></title><secondary-title><style face="normal" font="default" size="100%">Ann Biomed Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Ann Biomed Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Action Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Body Surface Potential Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Calibration</style></keyword><keyword><style  face="normal" font="default" size="100%">Computer Simulation</style></keyword><keyword><style  face="normal" font="default" size="100%">Electric Conductivity</style></keyword><keyword><style  face="normal" font="default" size="100%">Fluorescent Dyes</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Models, Cardiovascular</style></keyword><keyword><style  face="normal" font="default" size="100%">Sheep</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword><keyword><style  face="normal" font="default" size="100%">Video Recording</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1997</style></year><pub-dates><date><style  face="normal" font="default" size="100%">07/1997</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/9236983</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">25</style></volume><pages><style face="normal" font="default" size="100%">713-25</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;A charge-coupled device (CCD) camera was used to acquire movies of transmembrane activity from thin slices of sheep ventricular&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;epicardial&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;muscle stained with a voltage-sensitive dye. Compared with photodiodes, CCDs have high spatial resolution, but low temporal resolution. Spatial resolution in our system ranged from 0.04 to 0.14 mm/pixel; the acquisition rate was 60, 120, or 240 frames/sec. Propagating waves were readily visualized after subtraction of a background image. The optical signal had an amplitude of 1 to 6 gray levels, with signal-to-noise ratios between 1.5 and 4.4. Because CCD cameras integrate light over the frame interval, moving objects, including propagating waves, are blurred in the resulting movies. A computer model of such an integrating&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;imaging&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;system was developed to study the effects of blur, noise, filtering, and quantization on the ability to measure conduction velocity and action potential duration (APD). The model indicated that blurring, filtering, and quantization do not affect the ability to localize wave fronts in the optical data (i.e., no systematic error in determining spatial position), but noise does increase the uncertainty of the measurements. The model also showed that the low frame rates of the CCD camera introduced a systematic error in the calculation of APD: for cutoff levels &amp;gt; 50%, the APD was erroneously long. Both noise and quantization increased the uncertainty in the APD measurements. The optical measures of conduction velocity were not significantly different from those measured simultaneously with microelectrodes. Optical APDs, however, were longer than the electrically recorded APDs. This APD error could be reduced by using the 50% cutoff level and the fastest frame rate possible.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">4</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Davidenko, J M</style></author><author><style face="normal" font="default" size="100%">Pertsov, A V</style></author><author><style face="normal" font="default" size="100%">Salomonsz, R</style></author><author><style face="normal" font="default" size="100%">Baxter, Bill</style></author><author><style face="normal" font="default" size="100%">Jalife, J</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Spatiotemporal irregularities of spiral wave activity in isolated ventricular muscle.</style></title><secondary-title><style face="normal" font="default" size="100%">J Electrocardiol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Electrocardiol</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Animals</style></keyword><keyword><style  face="normal" font="default" size="100%">Cardiac Pacing, Artificial</style></keyword><keyword><style  face="normal" font="default" size="100%">Fluorescent Dyes</style></keyword><keyword><style  face="normal" font="default" size="100%">Heart Conduction System</style></keyword><keyword><style  face="normal" font="default" size="100%">Membrane Potentials</style></keyword><keyword><style  face="normal" font="default" size="100%">Optics and Photonics</style></keyword><keyword><style  face="normal" font="default" size="100%">Pericardium</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Tachycardia</style></keyword><keyword><style  face="normal" font="default" size="100%">Ventricular Function</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">1992</style></year><pub-dates><date><style  face="normal" font="default" size="100%">1992</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/1552240</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">24 Suppl</style></volume><pages><style face="normal" font="default" size="100%">113-22</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Voltage-sensitive dyes and high resolution optical mapping were used to analyze the characteristics of spiral waves of excitation in isolated ventricular myocardium. In addition, analytical techniques, which have been previously used in the study of the characteristics of spiral waves in chemical reactions, were applied to determine the voltage structure of the center of the rotating activity (ie, the core). During stable spiral wave activity local activation occurs in a periodic fashion (ie, 1:1 stimulus: response activation ratio) throughout the preparation, except at the core, which is a small elongated area where the activity is of low voltage and the activation ratio is 1:0. The voltage amplitude increases gradually from the center of the core to the periphery. In some cases, however, regular activation patterns at the periphery may coexist with irregular local activation patterns near the core. Such a spatiotemporal irregularity is attended by variations in the core size and shape and results from changes in the core position. The authors conclude that functionally determined reentrant activity in the heart may be the result of spiral waves of propagation and that local spatiotemporal irregularities in the activation pattern are the result of changes in the core position.&lt;/span&gt;&lt;/p&gt;</style></abstract></record></records></xml>