<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Wisneski, Kimberly</style></author><author><style face="normal" font="default" size="100%">Nicholas R Anderson</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">Smyth, Matt</style></author><author><style face="normal" font="default" size="100%">Moran, D</style></author><author><style face="normal" font="default" size="100%">Leuthardt, E C</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Unique cortical physiology associated with ipsilateral hand movements and neuroprosthetic implications.</style></title><secondary-title><style face="normal" font="default" size="100%">Stroke</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Stroke</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adolescent</style></keyword><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Artificial Limbs</style></keyword><keyword><style  face="normal" font="default" size="100%">Bionics</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain Mapping</style></keyword><keyword><style  face="normal" font="default" size="100%">Child</style></keyword><keyword><style  face="normal" font="default" size="100%">Dominance, Cerebral</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Hand</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Movement</style></keyword><keyword><style  face="normal" font="default" size="100%">Paresis</style></keyword><keyword><style  face="normal" font="default" size="100%">Prosthesis Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Stroke</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Volition</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">12/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18927456</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">39</style></volume><pages><style face="normal" font="default" size="100%">3351-9</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;BACKGROUND AND PURPOSE:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&lt;span class=&quot;highlight&quot;&gt;Brain computer interfaces&lt;/span&gt;&amp;nbsp;(BCIs) offer little direct benefit to patients with hemispheric stroke because current platforms rely on signals derived from the contralateral motor cortex (the same region injured by the stroke). For BCIs to assist hemiparetic patients, the implant must use unaffected cortex ipsilateral to the affected limb. This requires the identification of distinct electrophysiological features from the motor cortex associated with ipsilateral hand movements.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;In this study we studied 6 patients undergoing temporary placement of intracranial electrode arrays. Electrocorticographic (ECoG) signals were recorded while the subjects engaged in specific ipsilateral or contralateral hand motor tasks. Spectral changes were identified with regards to frequency, location, and timing.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Ipsilateral hand movements were associated with electrophysiological changes that occur in lower frequency spectra, at distinct anatomic locations, and earlier than changes associated with contralateral hand movements. In a subset of 3 patients, features specific to ipsilateral and contralateral hand movements were used to control a cursor on a screen in real time. In ipsilateral derived control this was optimal with lower frequency spectra.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;CONCLUSIONS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;There are distinctive cortical electrophysiological features associated with ipsilateral movements which can be used for device control. These findings have implications for patients with hemispheric stroke because they offer a potential methodology for which a single hemisphere can be used to enhance the function of a stroke induced hemiparesis.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">12</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Hinterberger, T.</style></author><author><style face="normal" font="default" size="100%">Widman, Guido</style></author><author><style face="normal" font="default" size="100%">Lal, T.N</style></author><author><style face="normal" font="default" size="100%">Jeremy Jeremy Hill</style></author><author><style face="normal" font="default" size="100%">Tangermann, Michael</style></author><author><style face="normal" font="default" size="100%">Rosenstiel, W.</style></author><author><style face="normal" font="default" size="100%">Schölkopf, B</style></author><author><style face="normal" font="default" size="100%">Elger, Christian</style></author><author><style face="normal" font="default" size="100%">Niels Birbaumer</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Voluntary brain regulation and communication with electrocorticogram signals.</style></title><secondary-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Epilepsy Behav</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Adult</style></keyword><keyword><style  face="normal" font="default" size="100%">Biofeedback, Psychology</style></keyword><keyword><style  face="normal" font="default" size="100%">Cerebral Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Dominance, Cerebral</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsies, Partial</style></keyword><keyword><style  face="normal" font="default" size="100%">Female</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Imagination</style></keyword><keyword><style  face="normal" font="default" size="100%">Male</style></keyword><keyword><style  face="normal" font="default" size="100%">Middle Aged</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Activity</style></keyword><keyword><style  face="normal" font="default" size="100%">Motor Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Signal Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Software</style></keyword><keyword><style  face="normal" font="default" size="100%">Somatosensory Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Theta Rhythm</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword><keyword><style  face="normal" font="default" size="100%">Writing</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">08/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18495541</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">13</style></volume><pages><style face="normal" font="default" size="100%">300-6</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;(BCIs) can be used for communication in writing without muscular activity or for learning to control seizures by voluntary regulation of&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;signals such as the electroencephalogram (EEG). Three of five patients with epilepsy were able to spell their names with electrocorticogram (ECoG) signals derived from motor-related areas within only one or two training sessions. Imagery of finger or tongue movements was classified with support-vector classification of autoregressive coefficients derived from the ECoG signals. After training of the classifier, binary classification responses were used to select letters from a&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;-generated menu. Offline analysis showed increased theta activity in the unsuccessful patients, whereas the successful patients exhibited dominant sensorimotor rhythms that they could control. The high spatial resolution and increased signal-to-noise ratio in ECoG signals, combined with short training periods, may offer an alternative for communication in complete paralysis, locked-in syndrome, and motor restoration.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record></records></xml>