<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Vansteensel, Mariska J</style></author><author><style face="normal" font="default" size="100%">Hermes, Dora</style></author><author><style face="normal" font="default" size="100%">Aarnoutse, Erik J</style></author><author><style face="normal" font="default" size="100%">Bleichner, Martin G</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author><author><style face="normal" font="default" size="100%">van Rijen, Peter C</style></author><author><style face="normal" font="default" size="100%">Leijten, Frans S S</style></author><author><style face="normal" font="default" size="100%">Ramsey, Nick F</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer interfacing based on cognitive control.</style></title><secondary-title><style face="normal" font="default" size="100%">Ann Neurol</style></secondary-title><alt-title><style face="normal" font="default" size="100%">Ann. Neurol.</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Cognition</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Epilepsy</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Image Processing, Computer-Assisted</style></keyword><keyword><style  face="normal" font="default" size="100%">Magnetic Resonance Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuropsychological Tests</style></keyword><keyword><style  face="normal" font="default" size="100%">Oxygen</style></keyword><keyword><style  face="normal" font="default" size="100%">Prefrontal Cortex</style></keyword><keyword><style  face="normal" font="default" size="100%">Psychomotor Performance</style></keyword><keyword><style  face="normal" font="default" size="100%">Spectrum Analysis</style></keyword><keyword><style  face="normal" font="default" size="100%">Time Factors</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2010</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2010</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/20517943</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">67</style></volume><pages><style face="normal" font="default" size="100%">809-16</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;OBJECTIVE:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Brain-computer interfaces (BCIs) translate deliberate intentions and associated changes in brain activity into action, thereby offering patients with severe paralysis an alternative means of communication with and control over their environment. Such systems are not available yet, partly due to the high performance standard that is required. A major challenge in the development of implantable BCIs is to identify cortical regions and related functions that an individual can reliably and consciously manipulate. Research predominantly focuses on the sensorimotor cortex, which can be activated by imagining motor actions. However, because this region may not provide an optimal solution to all patients, other neuronal networks need to be examined. Therefore, we investigated whether the cognitive control network can be used for BCI purposes. We also determined the feasibility of using functional magnetic resonance imaging (fMRI) for noninvasive localization of the cognitive control network.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;METHODS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;Three patients with intractable epilepsy, who were temporarily implanted with subdural grid electrodes for diagnostic purposes, attempted to gain BCI control using the electrocorticographic (ECoG) signal of the left dorsolateral prefrontal cortex (DLPFC).&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;RESULTS:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;All subjects quickly gained accurate BCI control by modulation of gamma-power of the left DLPFC. Prelocalization of the relevant region was performed with fMRI and was confirmed using the ECoG signals obtained during mental calculation localizer tasks.&lt;/p&gt;
&lt;h4 style=&quot;font-size: 13px; margin: 0px 0.25em 0px 0px; text-transform: uppercase; float: left; font-family: arial, helvetica, clean, sans-serif; line-height: 17px;&quot;&gt;INTERPRETATION:&amp;nbsp;&lt;/h4&gt;
&lt;p style=&quot;margin: 0px 0px 0.5em; font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The results indicate that the cognitive control network is a suitable source of signals for BCI applications. They also demonstrate the feasibility of translating understanding about cognitive networks derived from functional neuroimaging into clinical applications.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Brain-computer symbiosis.</style></title><secondary-title><style face="normal" font="default" size="100%">J Neural Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">J Neural Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2008</style></year><pub-dates><date><style  face="normal" font="default" size="100%">03/2008</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/18310804</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">5</style></volume><pages><style face="normal" font="default" size="100%">P1-P15</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;The theoretical groundwork of the 1930s and 1940s and the technical advance of computers in the following decades provided the basis for dramatic increases in human efficiency. While computers continue to evolve, and we can still expect increasing benefits from their use, the interface between humans and computers has begun to present a serious impediment to full realization of the potential payoff. This paper is about the theoretical and practical possibility that direct communication between the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;and the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;computer&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;&amp;nbsp;can be used to overcome this impediment by improving or augmenting conventional forms of human communication. It is about the opportunity that the limitations of our body's input and output capacities can be overcome using direct interaction with the&amp;nbsp;&lt;/span&gt;&lt;span class=&quot;highlight&quot; style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;brain&lt;/span&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;, and it discusses the assumptions, possible limitations and implications of a technology that I anticipate will be a major source of pervasive changes in the coming decades.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">1</style></issue></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Cincotti, F</style></author><author><style face="normal" font="default" size="100%">Bianchi, L</style></author><author><style face="normal" font="default" size="100%">Birch, Gary</style></author><author><style face="normal" font="default" size="100%">Guger, C</style></author><author><style face="normal" font="default" size="100%">Mellinger, Jürgen</style></author><author><style face="normal" font="default" size="100%">Scherer, Reinhold</style></author><author><style face="normal" font="default" size="100%">Schmidt, Robert N</style></author><author><style face="normal" font="default" size="100%">Yáñez Suárez, Oscar</style></author><author><style face="normal" font="default" size="100%">Gerwin Schalk</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">BCI meeting 2005 - Workshop on Technology: Hardware and Software.</style></title><secondary-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></secondary-title><alt-title><style face="normal" font="default" size="100%">IEEE Trans Neural Syst Rehabil Eng</style></alt-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Algorithms</style></keyword><keyword><style  face="normal" font="default" size="100%">Biotechnology</style></keyword><keyword><style  face="normal" font="default" size="100%">Brain</style></keyword><keyword><style  face="normal" font="default" size="100%">Communication Aids for Disabled</style></keyword><keyword><style  face="normal" font="default" size="100%">Computers</style></keyword><keyword><style  face="normal" font="default" size="100%">Electroencephalography</style></keyword><keyword><style  face="normal" font="default" size="100%">Equipment Design</style></keyword><keyword><style  face="normal" font="default" size="100%">Humans</style></keyword><keyword><style  face="normal" font="default" size="100%">Internationality</style></keyword><keyword><style  face="normal" font="default" size="100%">Man-Machine Systems</style></keyword><keyword><style  face="normal" font="default" size="100%">Neuromuscular Diseases</style></keyword><keyword><style  face="normal" font="default" size="100%">Software</style></keyword><keyword><style  face="normal" font="default" size="100%">User-Computer Interface</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2006</style></year><pub-dates><date><style  face="normal" font="default" size="100%">06/2006</style></date></pub-dates></dates><urls><web-urls><url><style face="normal" font="default" size="100%">http://www.ncbi.nlm.nih.gov/pubmed/16792276</style></url></web-urls></urls><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">128-31</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;&lt;span style=&quot;font-family: arial, helvetica, clean, sans-serif; font-size: 13px; line-height: 17px;&quot;&gt;This paper describes the outcome of discussions held during the Third International BCI Meeting at a workshop to review and evaluate the current state of BCI-related hardware and software. Technical requirements and current technologies, standardization procedures and future trends are covered. The main conclusion was recognition of the need to focus technical requirements on the users' needs and the need for consistent standards in BCI research.&lt;/span&gt;&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">2</style></issue></record></records></xml>